FFP2 Respirator machine
平面口罩机参数: Semi-Automatic Mask Machine l Power supply: 3.3KW mono Stage l Mask Size: 175mm*80-100mm (two or three layers) l Nonwoven (GMS): 10-50g l Capacity: 120 […]
平面口罩机参数: Semi-Automatic Mask Machine l Power supply: 3.3KW mono Stage l Mask Size: 175mm*80-100mm (two or three layers) l Nonwoven (GMS): 10-50g l Capacity: 120 […]
Burring Ability 100 / 200 KG/ hr Please write your offer here 2. Ability: to cremate (carrion and spoils) 350-400kg/hour
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production Shipping Volume Shipping Weight Delivery
Zhangjiagang Tengxiang Machinery Co., Ltd. Mobile: 0086-13962221749(whatsapp) Wechat: chncheumg Email: [email protected] Face Mask Machine for Coronavirus Disease COVID-19 Ø Overall Dimension:900mm*650mm*1380mm 2020-04-03
Hazardous medical waste: Clinical and related waste, arising from medical, nursing or comparable practices and waste 2. The unit should
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production Shipping Volume Shipping Weight Delivery
HICLOVER – Medical Environmental Model YD-30 (Custom Edition) Picture Burning Rate average 30 kgs/hour Feed Capacity average 40 kgs Paimary Combustion
Waste calorific value : 4000KCAL/KG INSULATION ·???????? Control panel — automatic operation Secondary Chamber : 2 Seconds @ 850degrees C
Light Weight Small-Scale Medical, Mobile Optional Type Model YD-30 Picture Burning Rate average 30 kgs/hour Feed Capacity average 40
Secondary Chamber Temperature * 1100 — 1300 deg. C Dimensional Sketch, Operation & Installation Manuals. Required Away — Gas
Items/Model TS30(PLC) Picture Burn Rate Average 30 kg/hour Feed Capacity Average 60kg per feeding Control Mode PLC(Programmable Logic Controller
Ø FUEL DIESEL/NATURAL GAS; NUMBER OF PRIMARY BURNERS & RATING: 2 @ 250kw Ø NUMBER OF SECONDARY BURNERS & RATING:
Model WS-35 Picture Burning Rate Average 35 kgs/hour Feed Capacity Average 80 kgs Main Combustion Chamber 460 Liters Secondary Combustion
Items/Model CA100 Picture Principle Medical Waste Incineration Treatment Burn Rate Average 100 kg/hour Feed Capacity Average 200kg/feeding Control Mode PLC(Programmable
the incinerator can be used to dispose Medical waste IV, used needles, used syringes, scalpels, used dressing material,personal protective equipments
HICLOVER – Containerized Mobile Incinerator Medical Waste Incinerator Model CA50 Model CA50 Picture Waste Treatment Medical Waste Incineration Treatment Feed Capacity
I’d like to receive more technical details e.g. fuel consumption for Small volumes of waste don’t appear to warrant the
Coronavirus Disease 2019 (COVID-19) pandemic continues all over the world, clinics,hospitals,goverment may need to consider on-site disposal for the infectious
Hospital Waste Management in Addition to Competitive prices as Pakistan is a competitive market. Air provide Electric Barometric indicator, door
Items/Model TS300(PLC) Principle Waste Incineration Treatment Burn Rate Average 250 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2000L
Model YD-100 Picture Burning Rate 100-150 kgs/hour Main Combustion Chamber 2000 Liters Secondary Combustion Chamber 500 Liters Feed Mode Manual
Incinerator utilities Fully automatic and simple to operate control panel g). insecticides/herbicides/pesticides a). bio medical waste/pharmaceutical waste o). alcoholic waste.
Model CA-200 Picture Burning Rate Typical 100 kgs/hour Primary Combustion Chamber 2000 Liters Secondary Combustion Chimney Yes Feed Mode Manual
INCINERATOR, DIESEL DRIVEN INSULATION Nominal Capacity : 50Kg/Hour batch load Calcium Silicate Thickness 25mm
Items/Model TS500(PLC) Picture Principle Waste Incineration Treatment Burn Rate 150-200 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2700L
Incinerators to be acceptable for the professional disposal of medical & clinical waste / garbage with a higher load capacity
Items/Model TS100(PLC) Picture Principle Waste Incineration Treatment Burn Rate 60-80 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L
Items/Model TS50(PLC) Picture Principle Solid Waste Incineration Burn Rate 30-45 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L
Model CA100 Picture Waste Treatment Medical Waste Incineration Treatment Feed Capacity Typical 100-200 kgs per feed Burning Rate Typical 100-120
We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator,
Incinerator 20 Kg Incinerator electrically operated including:  A cage for receipt of biomedical waste;  A combustion room with
Incinerator to have double combustion chamber and control quantity of dioxin and other gasses emitted without being detrimental. Estimated dimensions,
incinerator Providers.7) Burn rate: 15 – 20 Kg/h Mmedical waste incinerator capable of disposing up to 0.25cubic meter of infectious
incinerator for medical waste.Controlled air medical waste incinerator intended for incineration of bio-medical waste generated in a blood-processing center. The
Temperature Display & PLC Control Case Main Combustion Chamber Incinerator Main Body ***Primary Combustion Chamber Italy Oil/Gas Burner ***Chimney:10.0Meters ***Secondary
Waste Incinerator (Containerized Mobile Incinerator) Capacity: Typical 50 kgs per hour Model CA50 Internal Dimensions 100 x 80 x 70
Model TS30 oil fired waste small incinerator 30kgs/hr. Items/Model TS30(PLC) Picture Burn Rate Typical 20-30 kg/hour Feed Capacity Typical
Medical waste incineration system of 300 kg/hr burn rate with dual fuel (Gasoline and diesel) type, daily 8-16 hrs operation
Key Features: — Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator,
Volume 6 — Mobile Incinerator 10m Hose Pipe, indicate length One year Spare Parts Package for complete maintainability Burn Rate
Incinerator for Animal Crematory Pig Farm Model A1200 *** 3 sets Burners *** Good for animals or big pets ***
*** Primary combustion chamber & secondary combustion chamber *** Smoke filter chamber(dry scrubber) *** stainless steel chimney *** PLC auto.
MOC Generally confirming to IS Standards Type of burning operation Cylindrical Dimension Port Hole and Ladder for emission testing with
*** Double Combustion Chamber *** PLC auto control operation *** stainless steel chimney *** smoke filter chamber *** Italy oil/gas
3 Medical Waste Incinerator of 20 kg/hr capacity with double burner.Medical Waste Incineration Systems. I’m interested to ruin about 200
Smallest waste incinerator for small hospital average 10kgs per hour. with double(2) sets burner. Equipment Technical Specifications Model YD-10 Feed
Carburant Diesel The waste most include vary materials plastics, rubber, paper, grass, leaves, woods, fruits, packaging carton, and many others