Supply, Installation and commissioning of Waste Incineration system
The proposal must include the comprehensive description of the whole system: Total cost of supply, Installation, commissioning, Automatic feeding, automatic […]
The proposal must include the comprehensive description of the whole system: Total cost of supply, Installation, commissioning, Automatic feeding, automatic […]
2. A camera post-combustion gases : Cold filter plugging point -10 ° C max. DIESEL AND FOOD TANK BURNER The
company. Our products main for small waste output. For hospital straight, local at hospital, or portable/mobile incinerator to a single
2. What’s your minimum capacity and maximum capacity incinerator. 3. You do provide secodn hand incinerator in good working condition.
Disinfecting/sterilizing the contaminated medical wastes, main combustion chamber, post combustion chamber, heat exchanger, ash removal components and flue gas treatment
50 kg/ hour capacity incinerators · Burning Rate: 50kos/hr · Feed Capacity: 150kqs · Main Combustion Chamber: 900 Dimensions ·
HICLOVER – Containerized Mobile Incinerator Medical Waste Incinerator Model CA50 Model CA50 Picture Waste Treatment Medical Waste Incineration Treatment Feed Capacity
HICLOVER – Medical Environmental Model YD-20 Picture Burning Rate Average 20 kgs/hour Feed Capacity Average 60 kgs/feeding Primary Combustion Chamber
Items/Model CA100 Picture Principle Medical Waste Incineration Treatment Burn Rate Average 100 kg/hour Feed Capacity Average 200kg/feeding Control Mode PLC(Programmable
Model WS-35 Picture Burning Rate Typical 35 kgs/hour Feed Capacity Typical 80 kgs Primary Combustion Chamber 460 Liters Secondary Combustion
Items/Model TS30(PLC) Picture Burn Rate Average 30 kg/hour Feed Capacity Average 60kg per feeding Control Mode PLC(Programmable Logic Controller
Light Weight Small-Scale Medical, Mobile Optional Type Related Incinerator A2400 Medical Waste Incinerator N95 Face Mask Machine Production Line on
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production Shipping Volume Shipping Weight Delivery
HICLOVER Medical Waste Incinerator in Stock(Finished and Semi-finished and New Production) Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type
HICLOVER Medical Waste Incinerator in Stock(Finished and Semi-finished and New Production) Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type
HICLOVER Medical Waste Incinerator in Stock(Finished and Semi-finished and New Production) Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type
Q: what is kind of waste can use in this equipment?A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste. Q: Remedy capacityA: Average Capacity calculated by medical waste(lower calorific power (L.C.P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity. Clover incinerator use time daily to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use. Generally, we proposal little lab, little clinic use capability under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people per day. If there are 200 sickbed in the hospital, that’s mean you need one incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator.*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. Q: Assembly and TestingA: We provide
CO – Shouldn’t exceed 100 mg/m3 SO2 – Shouldn’t exceed 400 mg/m3 HF – (Hydrogen fluoride) Shouldn’t exceed 9.0 mg/m3
it’s also very important for us to know whether the unit is qualified to deal with cytotoxic waste and also
Medical waste is posing a growing problem all around the world, jeopardizing the health of staff, patients, disposal employees and
HIGH TECH PYROLYTIC MEDICAL WASTE INCINERATOR 1. 21. The de- ashing must be performed in the bottom of the combustion
Incineration is the most obvious solution for total destruction of municipal waste, avoiding all the direct and indirect risks associated with other disposal methods.Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same place where it was generated to avoid cross-contamination risk and to keep waste treatment costs at acceptable level. — Upgrade/Downgrade Burning Rate WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. ※Main Feature:–Three Combustion Chambers or A/B Main Combustion Chamber— Double or Three Italy Burner–Burning Rate: 80-800kgs per hour–Combustion Chamber: 1.0M3-10.0M3※Optional Function/Parts/Material/Burning Rate: — Stainless Steel Chimney — Dry Smoke Filter Chamber— Chimney Height Custom Made— Semi-Automatic Waste Feeding— 3-Section Wet Scrubber System— Movable Platform Feeding Door— Additional Burner Mobile: +86-13813931455(whatsapp/wechat)Website: www.clovertech.com.cn Email: [email protected]Email: [email protected] Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Quantity: Two [2] with complete accessories. Kinds of wastes being used: GENERAL WASTE.Polyester, polypropylene, polystyrene, vinyl acetate plastic, synthetic plastics,
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal
Automatic loading and reloading with capacity of 10 to 12 tons per day working with gas treatment procedures and gasoline
Key Features: General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.— Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators.— System solutions for medical waste environmental.— High burn rate, from 5kgs to 1000kgs per hour.— New Design for pet animal cremation business. — HICLOVER, trusted partner with years of experience. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. — Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, Mobile: +86-13813931455(whatsapp/wechat)Website: www.clovertech.com.cn Email: [email protected]Email: [email protected] Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
13. Civil works, installation and Comnuss!Onmg lndusive of civil works (brick wall incinerator house Type of waste for disposal
— Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator. — System solutions for medical waste environmental. — High burn rate, from 5kgs to 1000kgs per hour. — New Design for pet animal cremation business. — HICLOVER, trusted partner with years of experience. Nanjing Clover Medical Technology Co.,Ltd.. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30
○ Containerized Mobile Incinerator(CA Model) HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront
We’ve got a 70 bed hospital in namibia. However there is a potential of getting clients from other regional doctors.
Requirements and specifications for the process of distribution, installation, operation and guarantee the three incinerators for burning and incineration of
– 150 KG/HR – Compliant with EU rules, Directive 2000/76/EC – Fuel type: Diesel – Easy management and maintenance
1. Technical specifications; I. Size of the Incinerator 4,410W x 3,037L x 4,836H mm II. Ability of the Incinerator Medical
Incinerator but the size of chamber > 2000 x 1200 mm. Prepare for burn LIQUID Waste +/- 20 liter/hr. C:
1) Electricity Supply: (a) Mains Supply: (I) Single Stage supply; 220 — 240V, 50Hz (ii) Three Stage supply; 380 —
2. Heavy duty steel, heat resistant coating, stainless steel lid, painted tubular steel frame, 2-blowers, axial vane, suitable drum (S/S,
Medical incinerator with a 10 kg/hour (15 lbs/hour) capacity shall be constructed on the site, complete with Stacks, control panels
burn between 5000-10000 kg per hour.Mostly waste from crude oil tanks. Construction, installation and 6 weeks maintenance cost including specifications.CMSD
Incenerator Supply, installation and testing of medical waste incinerator with a capacity of 75 kilograms / hour, operated by LPG
each day, necessary number of units -10 to 25 numbers Installing different sort of waste Management systems preferably Incineration and
a. 2.5 metric tons per day healthcare waste incinerator b. 1.5 metric tons per day healthcare waste incinerator c. 300
Parameter Compliance Type of Waste To treat medical waste, categories A,B,C,D,E Type of Incinerator Pyrolytic Nominal Burn rate 50 t0
Double Combustion Chamber All waste incinerator design with double combustion chamber. High Temperature, Smoke Treatment,No black smoke, Environmentally friendly. Containerized
[China] Solid Waste Environmental online waste incineration industries development momentum is fierce, and the cleverest of capital chasing even appear
If burning and incineration is used, the equipment selected ought to be designed and sized to accommodate the waste produced,
uniform heating value near the design stage of the incinerator. Externally supplied fuel and electricity are necessary for the burners
Model YD-30M Primary Combustion Chamber Secondary Combustion Chamber Mix Combustion Chamber Smoke Filter Chamber Incinerator Control Case Stainless Steel Chimney:
Dual heat burners and dual chamber incinerator Burning capacity up to 30 Kg per hour Main Product List Primary Combustion