Waste is thermally decomposed in the primary chamber at temperatures of 800 °C +. The resulting gaseous products are completely oxidized in the secondary chamber at higher temperatures with sufficient resident time. Other specifications are as follows. A combustion chamber of waste:
* Perfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load
* A burner of lighting which the use is limited to the ignition of waste. 
* Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory. 
* The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminum and insulates bricks in order to assure a minimum temperature on   the outside sheet metal.
* Composition of the refractory
| Burning Capacity | Max. 200kgs/h | |
| Auxiliary Fuel | Diesel | |
| Type of Burner | Monoblock automatic burners | |
| Temperatures | Primary Chamber: 800°C ± 50°C Secondary Chamber: 1300°C ± 50°C | |
| Type | Static solid hearth | |
| Material of Construction | Mild Steel | |
| Refractory thickness | 115 mm thick | |
| Material | Refractory bricks | |
| Insulation thickness | 50 mm thick | |
| Waste Charging | Manual | |
| Ash Removal | Manual | |
| Type | Static solid hearth | |
| Material of Construction | Mild Steel | |
| Refractory thickness | 115 mm thick | |
| Material | Refractory bricks | |
| Insulation thickness | 50 mm thick | |
| Type | Centrifugal | |
| Modulation | Manual damper control | |
| Material of Construction | Mild Steel | |
| Type of temperature controller | Digital | |
| Finish & painting type | Double coat  | |
| Material of construction & capacity | Mild Steel/ Plastic, suitable capacity | |
| Other Standard Accessories | Diesel oil level indicator, piping with valves & Non-return valve | |
| Visual Checking of Fuel | Provided | |
| No. of Burners | 2 one in primary and in secondary chamber) | |
| Type & Model | Monoblock automatic oil fired | |
| Make | Riello | |
| Fuel | Diesel | |
| Fuel delivery | 10 C 20 kg/h | |
| Firing stage | 1 | |
| Thermal power | 118 C 236 kW | |
| Motor power | 240 W | |
| Pump pressure | 10 C 12 bar (standard calibration), Max. pressure 15 bar | |
| Electrical supply | Single phase 220V, 50Hz. | |
| Material of construction | Burnt bricks | |
| Height | 9 meters from ground level | |